Use this to find facility ventilation levels for each room. If unable to find the facility use this view to enter the data. When done manually transfer all the data to the CAB form.

A PAD computer is suggested but this can be done on a smartphone.

Search Results (select link to load survey or start adding data for a new survey.)

1. Atlantic City Train ACY.txt . view file

Check and Update the CAB with this data: Go to CAB data Atlantic City Train ACY s . f

Facility Data Loaded: Atlantic City Train ACY.txt

Reports

Copy and paste this data into an email, spreadsheet, or document for your records.

0123456 789 101112131415
Room
Panel
Num
Room Name Room
Length
(ft-in)
Room
Width
(ft-in)
Room
Height
(ft-in)
Vent
Length
(in)
Vent
Width or
Diameter
(in)
Vent Air
ft/min
(ventA + ventB + ventC
+ ventD*2 + ventE*4...)
Room
sq-ft
Room
cu-ft
Vent
CFM
cuft/min
Vent
CFH
cuft/hr
Num
of
Vents
ACH
Control
Zone #
Vents
Clear
yes no
System
ON yes
no fail
eACH
UV-C
eACH
Far UV
ACH
Other
wACH
eACH
ACH
Total
1. Train Car 68 9 9 48 4 220*17 612 5508 4986.6 299196 17
54.3
zone Yes Yes 54.3
Total Space Aggregate 612 5508 4986.6 299196 17
54.3
Max-----
54.3
---
0
0
0
54.3
includes 0 Min-----
54.3
---
54.3
excludes 0 Lowest-----
54.3
---
0
0
0
54.3
Average ACH
affected by room sizes
-----
54.3
---
0
0
0
54.3
Facility
Panel
R
Multiple Vents Analysis na na na 0 0 4986.6 299196 17
0

ACH Report end


ACH Risk / Benefit Levels

Does not include facilities with Caution Status because there is no ACH data

Very
Low
Very
Low
Low
Low
Low
Low
Med
Med
Med
Med
Med
Med
Elite
Elite
Elite
Elite
Risk / Benefit Scale
with ACH Levels
worst benefit
most risk
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15+ best benefit
least risk
Count (ACH)1 1
Percent (ACH)100%0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 100
Count (with eACH or wACH or oACH)1 1
Percent (with eACH or wACH or oACH)100%0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 100
Benefit Level (ACH avg)
X
Benefit Level (with eACH or wACH or oACH avg)
X

Facility Name and Location: Atlantic City Train ACY

Comments: Manual observations 01/26/2023 23:07:20. Manual observations 01/26/2023 22:39:47. 220 4 1in x 48in vents 17 vents. Space size 4x4+4 17 panels x 4 ft = 68 ft x 8 ft x 9 ft high. Readings are the same as PHL train. Site Survey used instruments to measure ventilation and space size.





Benefit Report end


Carbon Footprint

Climate Change Carbon Load Parameters

Power Entries: Calculate Power Manually Enter Power Total Mechanical Watts

Unoccupied Power Percent (1-100): %

Factors

Occupancy (hrs/annual days): (e.g. 24/365) Occupancy Duty Cycle (1-100): %

Mech Watts / CFM:

UV Other Watts / Cu-Ft: UV-C Far UV Other

UV Other Watts / Sq-Ft: UV-C Far UV Other

UV Watts: Use CuFt Use SqFt

CO2 lbs. per kWh:

Metrics

Rooms: 1
Square Feet: 612
Cubic Feet: 5508
CFM: 4986.6
Occupancy (hrs/days): 16/365

ACH (avg): 54.3
ACH (max): 54.3
ACH (min not zero): 54.3

Climate Change Annual Carbon Load

Watts Mechanical: 2,583
Watts UV-C: 0
Watts UV-Far: 0
Watts Other: 0
Watts Total: 2,583

Occupancy: 16 Hrs . 365 Days . 5840 Total Hours
Occupancy Duty Cycle (1-100): 95%
Occupied Hours: 5548

Occupied Kilo Watt Hours (kWh): 14,331
Unoccupied Kilo Watt Hours (kWh): 1,433
Total Kilo Watt Hours (kWh): 15,764

Total Watts per sqft: 4.22
Total Watts per cuft: 0.468
Total Watts per 1000 sqft: 4220

Co2 (annual) lbs. Tons Metric Tons
Occupied 12,754 6.4 5.8
Unoccupied 1,275 0.6 0.6
Total 14,030 7 6.4

CO2 lbs. Tons Metric Tons
per 1000 sqft 22924 11.5 10.4
per 1 sqft 22.925 - -
per 1 cuft 2.547 - -


CAB v 0.11 R 2

02:25:23 Start Time
02:25:23 End Time
0 Seconds

5.026003 cab pid: 3049175 httpd pid: error pid: