Use this to find facility ventilation levels for each room. If unable to find the facility use this view to enter the data. When done manually transfer all the data to the CAB form.

A PAD computer is suggested but this can be done on a smartphone.

Search Results (select link to load survey or start adding data for a new survey.)

1. Atlantic City Train PHL.txt . view file

Check and Update the CAB with this data: Go to CAB data Atlantic City Train PHL s . f

Facility Data Loaded: Atlantic City Train PHL.txt

Reports

Copy and paste this data into an email, spreadsheet, or document for your records.

0123456 789 101112131415
Room
Panel
Num
Room Name Room
Length
(ft-in)
Room
Width
(ft-in)
Room
Height
(ft-in)
Vent
Length
(in)
Vent
Width or
Diameter
(in)
Vent Air
ft/min
(ventA + ventB + ventC
+ ventD*2 + ventE*4...)
Room
sq-ft
Room
cu-ft
Vent
CFM
cuft/min
Vent
CFH
cuft/hr
Num
of
Vents
ACH
Control
Zone #
Vents
Clear
yes no
System
ON yes
no fail
eACH
UV-C
eACH
Far UV
ACH
Other
wACH
eACH
ACH
Total
1. Train Car 68 8 9 4 48 230*17 544 4896 5213.3 312798 17
63.8
zone Yes Yes 63.8
2. Train Car Estimate 2 68 8 9 4 48 216*17 544 4896 4895.9 293754 17
59.9
59.9
3. Train Car Estimate 3 68 9 9 4 48 216*17 612 5508 4895.9 293754 17
53.3
53.3
Total Space Aggregate 1700 15300 15005.1 900306 51
58.8
Max-----
63.8
---
0
0
0
63.8
includes 0 Min-----
53.3
---
53.3
excludes 0 Lowest-----
53.3
---
0
0
0
53.3
Average ACH
affected by room sizes
-----
59
---
0
0
0
59
Facility
Panel
R
Multiple Vents Analysis na na na 0 0 15005.1 900306 51
0

ACH Report end


ACH Risk / Benefit Levels

Does not include facilities with Caution Status because there is no ACH data

Very
Low
Very
Low
Low
Low
Low
Low
Med
Med
Med
Med
Med
Med
Elite
Elite
Elite
Elite
Risk / Benefit Scale
with ACH Levels
worst benefit
most risk
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15+ best benefit
least risk
Count (ACH)3 3
Percent (ACH)100%0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 100
Count (with eACH or wACH or oACH)3 3
Percent (with eACH or wACH or oACH)100%0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 100
Benefit Level (ACH avg)
X
Benefit Level (with eACH or wACH or oACH avg)
X

Facility Name and Location: Atlantic City Train PHL

Comments: 230 4 1in x 48in vents 17 vents Left side center cabin 240 track B, 190 track A. First reading combined 230. Space size 4x4+4 17 panels x 4 ft = 68 ft x 8 ft x 9 ft high. Took reading again after first result, same numbers. Estimate 2 based on average. Site Survey used instruments to measure ventilation and space size.





Benefit Report end


Carbon Footprint

Climate Change Carbon Load Parameters

Power Entries: Calculate Power Manually Enter Power Total Mechanical Watts

Unoccupied Power Percent (1-100): %

Factors

Occupancy (hrs/annual days): (e.g. 24/365) Occupancy Duty Cycle (1-100): %

Mech Watts / CFM:

UV Other Watts / Cu-Ft: UV-C Far UV Other

UV Other Watts / Sq-Ft: UV-C Far UV Other

UV Watts: Use CuFt Use SqFt

CO2 lbs. per kWh:

Metrics

Rooms: 3
Square Feet: 1700
Cubic Feet: 15300
CFM: 15005.1
Occupancy (hrs/days): 16/365

ACH (avg): 59
ACH (max): 63.8
ACH (min not zero): 53.3

Climate Change Annual Carbon Load

Watts Mechanical: 7,773
Watts UV-C: 0
Watts UV-Far: 0
Watts Other: 0
Watts Total: 7,773

Occupancy: 16 Hrs . 365 Days . 5840 Total Hours
Occupancy Duty Cycle (1-100): 95%
Occupied Hours: 5548

Occupied Kilo Watt Hours (kWh): 43,123
Unoccupied Kilo Watt Hours (kWh): 4,312
Total Kilo Watt Hours (kWh): 47,435

Total Watts per sqft: 4.572
Total Watts per cuft: 0.508
Total Watts per 1000 sqft: 4572

Co2 (annual) lbs. Tons Metric Tons
Occupied 38,379 19.2 17.4
Unoccupied 3,838 1.9 1.7
Total 42,217 21.1 19.2

CO2 lbs. Tons Metric Tons
per 1000 sqft 24833 12.4 11.3
per 1 sqft 24.834 - -
per 1 cuft 2.759 - -


CAB v 0.11 R 4