1. Blue Heron Country Club.txt . view file

Check and Update the CAB with this data: Go to CAB data Blue Heron Country Club s . f

Facility Data Loaded: Blue Heron Country Club.txt

Reports

Copy and paste this data into an email, spreadsheet, or document for your records.

0123456 789 101112131415
Room
Panel
Num
Room Name Room
Length
(ft-in)
Room
Width
(ft-in)
Room
Height
(ft-in)
Vent
Length
(in)
Vent
Width or
Diameter
(in)
Vent Air
ft/min
(ventA + ventB + ventC
+ ventD*2 + ventE*4...)
Room
sq-ft
Room
cu-ft
Vent
CFM
cuft/min
Vent
CFH
cuft/hr
Num
of
Vents
ACH
Control
Zone #
Vents
Clear
yes no
System
ON yes
no fail
eACH
UV-C
eACH
Far UV
ACH
Other
wACH
eACH
ACH
Total
1. Meeting Room 1 48 30 12 24 4 200*14 1440 17280 1866.6 111996 14
6.4
6.4
Total Space Aggregate 1440 17280 1866.6 111996 14
6.4
Max-----
6.4
---
0
0
0
6.4
includes 0 Min-----
6.4
---
6.4
excludes 0 Lowest-----
6.4
---
0
0
0
6.4
Average ACH
affected by room sizes
-----
6.4
---
0
0
0
6.4
Facility
Panel
R
Multiple Vents Analysis na na na 0 0 1866.6 111996 14
0

ACH Report end


ACH Risk / Benefit Levels

Does not include facilities with Caution Status because there is no ACH data

Very
Low
Very
Low
Low
Low
Low
Low
Med
Med
Med
Med
Med
Med
Elite
Elite
Elite
Elite
Risk / Benefit Scale
with ACH Levels
worst benefit
most risk
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15+ best benefit
least risk
Count (ACH)1 1
Percent (ACH)100%0 0 0 0 0 0 100 0 0 0 0 0 0 0 0 0
Count (with eACH or wACH or oACH)1 1
Percent (with eACH or wACH or oACH)100%0 0 0 0 0 0 100 0 0 0 0 0 0 0 0 0
Benefit Level (ACH avg)
X
Benefit Level (with eACH or wACH or oACH avg)
X

Facility Name and Location: Blue Heron Country Club

Comments: 14 vents 28x4 30x48x10 15 ft peak





Benefit Report end


Carbon Footprint

Climate Change Carbon Load Parameters

Power Entries: Calculate Power Manually Enter Power Total Mechanical Watts

Unoccupied Power Percent (1-100): %

Factors

Occupancy (hrs/annual days): (e.g. 24/365) Occupancy Duty Cycle (1-100): %

Mech Watts / CFM:

UV Other Watts / Cu-Ft: UV-C Far UV Other

UV Other Watts / Sq-Ft: UV-C Far UV Other

UV Watts: Use CuFt Use SqFt

CO2 lbs. per kWh:

Metrics

Rooms: 1
Square Feet: 1440
Cubic Feet: 17280
CFM: 1866.6
Occupancy (hrs/days): 16/365

ACH (avg): 6.4
ACH (max): 6.4
ACH (min not zero): 6.4

Climate Change Annual Carbon Load

Watts Mechanical: 967
Watts UV-C: 0
Watts UV-Far: 0
Watts Other: 0
Watts Total: 967

Occupancy: 16 Hrs . 365 Days . 5840 Total Hours
Occupancy Duty Cycle (1-100): 95%
Occupied Hours: 5548

Occupied Kilo Watt Hours (kWh): 5,364
Unoccupied Kilo Watt Hours (kWh): 536
Total Kilo Watt Hours (kWh): 5,901

Total Watts per sqft: 0.671
Total Watts per cuft: 0.055
Total Watts per 1000 sqft: 671

Co2 (annual) lbs. Tons Metric Tons
Occupied 4,774 2.4 2.2
Unoccupied 477 0.2 0.2
Total 5,252 2.6 2.4