Use this to find facility ventilation levels for each room. If unable to find the facility use this view to enter the data. When done manually transfer all the data to the CAB form.

A PAD computer is suggested but this can be done on a smartphone.

Search Results (select link to load survey or start adding data for a new survey.)

1. Chuck E Cheese EHT.txt . view file

Check and Update the CAB with this data: Go to CAB data Chuck E Cheese EHT s . f

Facility Data Loaded: Chuck E Cheese EHT.txt

Reports

Copy and paste this data into an email, spreadsheet, or document for your records.

0123456 789 101112131415
Room
Panel
Num
Room Name Room
Length
(ft-in)
Room
Width
(ft-in)
Room
Height
(ft-in)
Vent
Length
(in)
Vent
Width or
Diameter
(in)
Vent Air
ft/min
(ventA + ventB + ventC
+ ventD*2 + ventE*4...)
Room
sq-ft
Room
cu-ft
Vent
CFM
cuft/min
Vent
CFH
cuft/hr
Num
of
Vents
ACH
Control
Zone #
Vents
Clear
yes no
System
ON yes
no fail
eACH
UV-C
eACH
Far UV
ACH
Other
wACH
eACH
ACH
Total
1. One section 14 14 15 diameter 14 500 196 2940 534.2 32052 1
10.9
10.9
2. Whole room 84 84 15 diameter 14 18000 1500 7056 105840 20835.2 1250112 2
11.8
11.8
Total Space Aggregate 7252 108780 21369.4 1282164 3
11.7
Max-----
11.8
---
0
0
0
11.8
includes 0 Min-----
10.9
---
10.9
excludes 0 Lowest-----
10.9
---
0
0
0
10.9
Average ACH
affected by room sizes
-----
11.3
---
0
0
0
11.3
Facility
Panel
R
Multiple Vents Analysis na na na 0 0 21369.4 1282164 3
0

ACH Report end


ACH Risk / Benefit Levels

Does not include facilities with Caution Status because there is no ACH data

Very
Low
Very
Low
Low
Low
Low
Low
Med
Med
Med
Med
Med
Med
Elite
Elite
Elite
Elite
Risk / Benefit Scale
with ACH Levels
worst benefit
most risk
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15+ best benefit
least risk
Count (ACH)2 1 1
Percent (ACH)100%0 0 0 0 0 0 0 0 0 0 50 50 0 0 0 0
Count (with eACH or wACH or oACH)2 1 1
Percent (with eACH or wACH or oACH)100%0 0 0 0 0 0 0 0 0 0 50 50 0 0 0 0
Benefit Level (ACH avg)
X
Benefit Level (with eACH or wACH or oACH avg)
X

Facility Name and Location: Chuck E Cheese EHT

Comments: 7*2 ft 14x14 ft 15 ft height 48x48 vent 35 vents 6x6 vents = 36 + 3 vents. Vent is really 14 in neck. Room size 14*6=84 ft x 84 ft. Total cfm 500*36=18000 + 500*3 = 1500 06/26/2022 observations no measurement tools. There is massive ventilation in the facility assume 500 FPM per vent. Ventilation is on all the time.





Benefit Report end


Carbon Footprint

Climate Change Carbon Load Parameters

Power Entries: Calculate Power Manually Enter Power Total Mechanical Watts

Unoccupied Power Percent (1-100): %

Factors

Occupancy (hrs/annual days): (e.g. 24/365) Occupancy Duty Cycle (1-100): %

Mech Watts / CFM:

UV Other Watts / Cu-Ft: UV-C Far UV Other

UV Other Watts / Sq-Ft: UV-C Far UV Other

UV Watts: Use CuFt Use SqFt

CO2 lbs. per kWh:

Metrics

Rooms: 2
Square Feet: 7252
Cubic Feet: 108780
CFM: 21369.4
Occupancy (hrs/days): 16/365

ACH (avg): 11.3
ACH (max): 11.8
ACH (min not zero): 10.9

Climate Change Annual Carbon Load

Watts Mechanical: 11,069
Watts UV-C: 0
Watts UV-Far: 0
Watts Other: 0
Watts Total: 11,069

Occupancy: 16 Hrs . 365 Days . 5840 Total Hours
Occupancy Duty Cycle (1-100): 95%
Occupied Hours: 5548

Occupied Kilo Watt Hours (kWh): 61,413
Unoccupied Kilo Watt Hours (kWh): 6,141
Total Kilo Watt Hours (kWh): 67,554

Total Watts per sqft: 1.526
Total Watts per cuft: 0.101
Total Watts per 1000 sqft: 1526

Co2 (annual) lbs. Tons Metric Tons
Occupied 54,657 27.3 24.8
Unoccupied 5,466 2.7 2.5
Total 60,123 30.1 27.3

CO2 lbs. Tons Metric Tons
per 1000 sqft 8290 4.1 3.8
per 1 sqft 8.291 - -
per 1 cuft 0.553 - -


CAB v 0.11 R 3