Use this to find facility ventilation levels for each room. If unable to find the facility use this view to enter the data. When done manually transfer all the data to the CAB form.

A PAD computer is suggested but this can be done on a smartphone.

Search Results (select link to load survey or start adding data for a new survey.)

1. Crab Trap.txt . view file

Check and Update the CAB with this data: Go to CAB data Crab Trap s . f

Facility Data Loaded: Crab Trap.txt

Reports

Copy and paste this data into an email, spreadsheet, or document for your records.

0123456 789 101112131415
Room
Panel
Num
Room Name Room
Length
(ft-in)
Room
Width
(ft-in)
Room
Height
(ft-in)
Vent
Length
(in)
Vent
Width or
Diameter
(in)
Vent Air
ft/min
(ventA + ventB + ventC
+ ventD*2 + ventE*4...)
Room
sq-ft
Room
cu-ft
Vent
CFM
cuft/min
Vent
CFH
cuft/hr
Num
of
Vents
ACH
Control
Zone #
Vents
Clear
yes no
System
ON yes
no fail
eACH
UV-C
eACH
Far UV
ACH
Other
wACH
eACH
ACH
Total
1. Back Dining Room 60 40 12 12 12 350*21 2400 28800 7350 441000 21
15.3
15.3
2. Front Dining Room 40 40 9 24 6 350*9 350*8 1600 14400 5950 357000 17
24.7
24.7
3. Bar Area 40 40 12 24 6 350*11 1600 19200 3850 231000 11
12
12
Total Space Aggregate 5600 62400 17150 1029000 49
16.4
Max-----
24.7
---
0
0
0
24.7
includes 0 Min-----
12
---
12
excludes 0 Lowest-----
12
---
0
0
0
12
Average ACH
affected by room sizes
-----
17.3
---
0
0
0
17.3
Facility
Panel
R
Multiple Vents Analysis na na na 0 0 17150 1029000 49
0

ACH Report end


ACH Risk / Benefit Levels

Does not include facilities with Caution Status because there is no ACH data

Very
Low
Very
Low
Low
Low
Low
Low
Med
Med
Med
Med
Med
Med
Elite
Elite
Elite
Elite
Risk / Benefit Scale
with ACH Levels
worst benefit
most risk
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15+ best benefit
least risk
Count (ACH)3 1 2
Percent (ACH)100%0 0 0 0 0 0 0 0 0 0 0 0 33.3 0 0 66.6
Count (with eACH or wACH or oACH)3 1 2
Percent (with eACH or wACH or oACH)100%0 0 0 0 0 0 0 0 0 0 0 0 33.3 0 0 66.6
Benefit Level (ACH avg)
X
Benefit Level (with eACH or wACH or oACH avg)
X

Facility Name and Location: Crab Trap

Comments: Room 1 12 vents + 6 + 3 12x12 vents 28x15 3 ft strides google is 60x40, Section 6x40x12 ft 2 vents 12x12, use as sanity check on room size. Room 2 9 6x24 vents google 40x40 48X24 ceiling vent = 6*8x24 = + 8 vents. 350 FPM. Ceilings are raised in center, 8ft at wall ~ 15ft at peak for average of 12ft. Needed to tell host to turn on fans, they did immediately, it a seafood restaurant they understand ventilation needs. Building is larger than surveyed space.





Benefit Report end


Carbon Footprint

Climate Change Carbon Load Parameters

Power Entries: Calculate Power Manually Enter Power Total Mechanical Watts

Unoccupied Power Percent (1-100): %

Factors

Occupancy (hrs/annual days): (e.g. 24/365) Occupancy Duty Cycle (1-100): %

Mech Watts / CFM:

UV Other Watts / Cu-Ft: UV-C Far UV Other

UV Other Watts / Sq-Ft: UV-C Far UV Other

UV Watts: Use CuFt Use SqFt

CO2 lbs. per kWh:

Metrics

Rooms: 3
Square Feet: 5600
Cubic Feet: 62400
CFM: 17150
Occupancy (hrs/days): 16/365

ACH (avg): 17.3
ACH (max): 24.7
ACH (min not zero): 12

Climate Change Annual Carbon Load

Watts Mechanical: 8,884
Watts UV-C: 0
Watts UV-Far: 0
Watts Other: 0
Watts Total: 8,884

Occupancy: 16 Hrs . 365 Days . 5840 Total Hours
Occupancy Duty Cycle (1-100): 95%
Occupied Hours: 5548

Occupied Kilo Watt Hours (kWh): 49,287
Unoccupied Kilo Watt Hours (kWh): 4,929
Total Kilo Watt Hours (kWh): 54,215

Total Watts per sqft: 1.586
Total Watts per cuft: 0.142
Total Watts per 1000 sqft: 1586

Co2 (annual) lbs. Tons Metric Tons
Occupied 43,865 21.9 19.9
Unoccupied 4,387 2.2 2
Total 48,252 24.1 21.9

CO2 lbs. Tons Metric Tons
per 1000 sqft 8616 4.3 3.9
per 1 sqft 8.616 - -
per 1 cuft 0.773 - -


CAB v 0.11 R 4