1. FAA Technical Center Design Data Bld-300.txt . view file

Check and Update the CAB with this data: Go to CAB data FAA Technical Center Design Data Bld-300 s . f

Facility Data Loaded: FAA Technical Center Design Data Bld-300.txt

Reports

Copy and paste this data into an email, spreadsheet, or document for your records.

0123456 789 101112131415
Room
Panel
Num
Room Name Room
Length
(ft-in)
Room
Width
(ft-in)
Room
Height
(ft-in)
Vent
Length
(in)
Vent
Width or
Diameter
(in)
Vent Air
ft/min
(ventA + ventB + ventC
+ ventD*2 + ventE*4...)
Room
sq-ft
Room
cu-ft
Vent
CFM
cuft/min
Vent
CFH
cuft/hr
Num
of
Vents
ACH
Control
Zone #
Vents
Clear
yes no
System
ON yes
no fail
eACH
UV-C
eACH
Far UV
ACH
Other
wACH
eACH
ACH
Total
1. Office Space na sqft na sqft 10 na na na 37525 375250 43300 2598000 1
6.9
AH 1 6.9
2. Auditorium na sqft na sqft 10 na na na 5571 55710 9460 567600 1
10.1
AH 2 10.1
3. Office Space na sqft na sqft 10 na na na 33497 334970 29000 1740000 1
5.1
AH 3 5.1
4. Office Space na sqft na sqft 10 na na na 23508 235080 35000 2100000 1
8.9
AH 4 8.9
5. Atrium na sqft na sqft 64 na na na 64158 4106112 25500 1530000 1
0.3
AH 5 0.3
6. Office Space na sqft na sqft 10 na na na 22089 220890 22000 1320000 1
5.9
AH 6 5.9
7. Office Space na sqft na sqft 10 na na na 20017 200170 22000 1320000 1
6.5
AH 7 6.5
8. Office Space na sqft na sqft 10 na na na 26289 262890 22000 1320000 1
5
AH 8 5
9. Office Space na sqft na sqft 10 na na na 16208 162080 22750 1365000 1
8.4
AH 9 8.4
10. Atrium Corridors na sqft na sqft 10 na na na 35228 352280 25230 1513800 1
4.2
AH 10 4.2
11. Office Space na sqft na sqft 10 na na na 15055 150550 21940 1316400 1
8.7
AH 11 8.7
12. Office Space na sqft na sqft 10 na na na 14314 143140 18360 1101600 1
7.6
AH 12 7.6
13. Office Space na sqft na sqft 10 na na na 22149 221490 28260 1695600 1
7.6
AH 13 7.6
14. Lab Space (Red Brick Building) na sqft na sqft 10 na na na 60828 608280 42080 2524800 1
4.1
AH 14 4.1
15. Lab Space (Red Brick Building) na sqft na sqft 10 na na na 60833 608330 41500 2490000 1
4
AH 15 4
16. Metal Shop na sqft na sqft 10 na na na 10513 105130 25295 1517700 1
14.4
AH 16 14.4
17. Cafeteria Dining Area na sqft na sqft 10 na na na 7534 75340 21225 1273500 1
16.9
AH 17 16.9
18. Office Space na sqft na sqft 10 na na na 20377 203770 12375 742500 1
3.6
AH 18 3.6
19. Cafeteria Kitchen Area na sqft na sqft 10 na na na 8258 82580 11870 712200 1
8.6
AH 20 8.6
20. Office Space na sqft na sqft 10 na na na 6163 61630 8765 525900 1
8.5
AH 21 8.5
21. Kitchen Equipment Only na na N/A na na na N/A 0 5000 300000 1
0
AH 22 0
Total Space Aggregate 510114 8565672 492910 29574600 21
3.4
Max-----
16.9
---
0
0
0
16.9
includes 0 Min-----
0
---
0
excludes 0 Lowest-----
0.3
---
0
0
0
0.3
Average ACH
affected by room sizes
-----
6.9
---
0
0
0
6.9
Facility
Panel
R
Multiple Vents Analysis na na na 0 0 492910 29574600 21
0

ACH Report end


ACH Risk / Benefit Levels

Does not include facilities with Caution Status because there is no ACH data

Very
Low
Very
Low
Low
Low
Low
Low
Med
Med
Med
Med
Med
Med
Elite
Elite
Elite
Elite
Risk / Benefit Scale
with ACH Levels
worst benefit
most risk
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15+ best benefit
least risk
Count (ACH)212 1 3 3 2 2 5 1 1 1
Percent (ACH)100%9.5 0 0 4.7 14.2 14.2 9.5 9.5 23.8 0 4.7 0 0 0 4.7 4.7
Count (with eACH or wACH or oACH)212 1 3 3 2 2 5 1 1 1
Percent (with eACH or wACH or oACH)100%9.5 0 0 4.7 14.2 14.2 9.5 9.5 23.8 0 4.7 0 0 0 4.7 4.7
Benefit Level (ACH avg)
X
Benefit Level (with eACH or wACH or oACH avg)
X

Facility Name and Location: FAA Technical Center Design Data Bld-300

Comments: Design data provided in spreadsheet on or about 06/13/22. The building must be tested to determine the actual ventilation performance level in each space and for the building as a whole. It is unclear if there are blocked or partially closed vents. Analysis suggests there may be 123 to 155 vents in the space. This is a spread span building with large spaces populated with cubicles.





Benefit Report end


Carbon Footprint

Climate Change Carbon Load Parameters

Power Entries: Calculate Power Manually Enter Power Total Mechanical Watts

Unoccupied Power Percent (1-100): %

Factors

Occupancy (hrs/annual days): (e.g. 24/365) Occupancy Duty Cycle (1-100): %

Mech Watts / CFM:

UV Other Watts / Cu-Ft: UV-C Far UV Other

UV Other Watts / Sq-Ft: UV-C Far UV Other

UV Watts: Use CuFt Use SqFt

CO2 lbs. per kWh:

Metrics

Rooms: 21
Square Feet: 510114
Cubic Feet: 8565672
CFM: 492910
Occupancy (hrs/days): 16/365

ACH (avg): 6.9
ACH (max): 16.9
ACH (min not zero): 0.3

Climate Change Annual Carbon Load

Watts Mechanical: 255,327
Watts UV-C: 0
Watts UV-Far: 0
Watts Other: 0
Watts Total: 255,327

Occupancy: 16 Hrs . 365 Days . 5840 Total Hours
Occupancy Duty Cycle (1-100): 95%
Occupied Hours: 5548

Occupied Kilo Watt Hours (kWh): 1,416,556
Unoccupied Kilo Watt Hours (kWh): 141,656
Total Kilo Watt Hours (kWh): 1,558,212

Total Watts per sqft: 0.5
Total Watts per cuft: 0.029
Total Watts per 1000 sqft: 500

Co2 (annual) lbs. Tons Metric Tons
Occupied 1,260,735 630.4 572
Unoccupied 126,074 63 57.2
Total 1,386,809 693.4 629.2

CO2 lbs. Tons Metric Tons
per 1000 sqft 2718 1.4 1.2
per 1 sqft 2.719 - -
per 1 cuft 0.162 - -


CAB v 0.11 R 22

22:14:40 Start Time
22:14:40 End Time
0 Seconds

5.026003 cab pid: 3404029 httpd pid: error pid: