Facility Data Loaded: FAA Technical Center Design Data Bld-316.txt
Copy and paste this data into an email, spreadsheet, or document for your records.
0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | |||||
Room Panel Num |
Room Name | Room Length (ft-in) |
Room Width (ft-in) |
Room Height (ft-in) |
Vent Length (in) |
Vent Width or Diameter (in) |
Vent Air ft/min (ventA + ventB + ventC + ventD*2 + ventE*4...) |
Room sq-ft |
Room cu-ft |
Vent CFM cuft/min |
Vent CFH cuft/hr |
Num of Vents |
Control Zone # |
Vents Clear yes no |
System ON yes no fail |
eACH UV-C |
eACH Far UV |
ACH Other wACH eACH |
ACH Total |
|
1. | Office Space | na sqft | na sqft | 10 | na | na | na | 24306 | 243060 | 27500 | 1650000 | 1 | AH 1 | 6.7 | ||||||
2. | Office Space | na sqft | na sqft | 10 | na | na | na | 23868 | 238680 | 28300 | 1698000 | 1 | AH 2 | 7.1 | ||||||
3. | Office Space | na sqft | na sqft | 10 | na | na | na | 27101 | 271010 | 37600 | 2256000 | 1 | AH 3 | 8.3 | ||||||
4. | Office Space | na sqft | na sqft | 10 | na | na | na | 27471 | 274710 | 28400 | 1704000 | 1 | AH 4 | 6.2 | ||||||
5. | Lab Space | na sqft | na sqft | 10 | na | na | na | 40210 | 402100 | 10000 | 600000 | 1 | AH 5 | 1.4 | ||||||
Total Space Aggregate | 142956 | 1429560 | 131800 | 7908000 | 5 | |||||||||||||||
Max | - | - | - | - | - | - | - | - | ||||||||||||
includes 0 Min | - | - | - | - | - | - | - | - | ||||||||||||
excludes 0 Lowest | - | - | - | - | - | - | - | - | ||||||||||||
Average ACH affected by room sizes | - | - | - | - | - | - | - | - | ||||||||||||
Facility Panel R |
Multiple Vents Analysis | na | na | na | 0 | 0 | 131800 | 7908000 | 5 |
ACH Report end
Does not include facilities with Caution Status because there is no ACH data
Low |
Low |
|||||||||||||||||
with ACH Levels |
most risk | 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15+ | least risk |
5 | 1 | 2 | 1 | 1 | ||||||||||||||
100% | 0 | 20 | 0 | 0 | 0 | 0 | 40 | 20 | 20 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||
5 | 1 | 2 | 1 | 1 | ||||||||||||||
100% | 0 | 20 | 0 | 0 | 0 | 0 | 40 | 20 | 20 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||
Facility Name and Location: FAA Technical Center Design Data Bld-316
Comments: Design data provided in spreadsheet on or about 06/13/22. The building must be tested to determine the actual ventilation performance level in each space and for the building as a whole. It is unclear if there are blocked or partially closed vents. Analysis suggests there may be 44 vents in the space. This is a spread span building with large spaces populated with cubicles.