About Us Contact Us

Find or Enter Facility ACH Data

clubhouse, house, model, restaurant, school, . for all
Find

example, house, etc
Reject

Reports Update

Add New Facility

Use this to find facility ventilation levels for each room. If unable to find the facility use this view to enter the data. When done manually transfer all the data to the CAB form.

A PAD computer is suggested but this can be done on a smartphone.

Search Results (select link to load survey or start adding data for a new survey.)

1. Talk of the Towne Diner Carneys Point.txt . view file

Check and Update the CAB with this data: Go to CAB data Talk of the Towne Diner Carneys Point s . f

Facility Data Loaded: Talk of the Towne Diner Carneys Point.txt

Reports

Copy and paste this data into an email, spreadsheet, or document for your records.

0123456 789 101112131415
Room
Panel
Num
Room Name Room
Length
(ft-in)
Room
Width
(ft-in)
Room
Height
(ft-in)
Vent
Length
(in)
Vent
Width or
Diameter
(in)
Vent Air
ft/min
(ventA + ventB + ventC
+ ventD*2 + ventE*4...)
Room
sq-ft
Room
cu-ft
Vent
CFM
cuft/min
Vent
CFH
cuft/hr
Num
of
Vents
ACH
Control
Zone #
Vents
Clear
yes no
System
ON yes
no fail
eACH
UV-C
eACH
Far UV
ACH
Other
wACH
eACH
ACH
Total
1. Room 1 54 20 8 diameter 15 350*4 1080 8640 1717.1 103026 4
11.9
Yes Yes 11.9
2. Room 2 30 24 8 24 24 200*2 720 5760 1600 96000 2
16.6
Yes Yes 16.6
Total Space Aggregate 1800 14400 3317.1 199026 6
13.8
Max-----
16.6
---
0
0
0
16.6
includes 0 Min-----
11.9
---
11.9
excludes 0 Lowest-----
11.9
---
0
0
0
11.9
Average ACH
affected by room sizes
-----
14.2
---
0
0
0
14.2
Facility
Panel
R
Multiple Vents Analysis na na na 0 0 3317.1 199026 6
0

ACH Report end


ACH Risk / Benefit Levels

Does not include facilities with Caution Status because there is no ACH data

Very
Low
Very
Low
Low
Low
Low
Low
Med
Med
Med
Med
Med
Med
Elite
Elite
Elite
Elite
Risk / Benefit Scale
with ACH Levels
worst benefit
most risk
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15+ best benefit
least risk
Count (ACH)2 1 1
Percent (ACH)100%0 0 0 0 0 0 0 0 0 0 0 50 0 0 0 50
Count (with eACH or wACH or oACH)2 1 1
Percent (with eACH or wACH or oACH)100%0 0 0 0 0 0 0 0 0 0 0 50 0 0 0 50
Benefit Level (ACH avg)
X
Benefit Level (with eACH or wACH or oACH avg)
X

Facility Name and Location: Talk of the Towne Diner Carneys Point

Comments: Visual observations. Room 2 24x30 6 2x2ft vents 2 48x48 exhaust. 200 cfm. Room 1 20x18 1 15in diameter vent 2 48x48 exhaust Room 0 20x36 3 15in diameter vents 2 48x48 exhaust. Massive cfm 350.





Benefit Report end


Carbon Footprint

Climate Change Carbon Load Parameters

Power Entries: Calculate Power Manually Enter Power Total Mechanical Watts

Unoccupied Power Percent (1-100): %

Factors

Occupancy (hrs/annual days): (e.g. 24/365) Occupancy Duty Cycle (1-100): %

Mech Watts / CFM:

UV Other Watts / Cu-Ft: UV-C Far UV Other

UV Other Watts / Sq-Ft: UV-C Far UV Other

UV Watts: Use CuFt Use SqFt

CO2 lbs. per kWh:

Metrics

Rooms: 2
Square Feet: 1800
Cubic Feet: 14400
CFM: 3317.1
Occupancy (hrs/days): 16/365

ACH (avg): 14.2
ACH (max): 16.6
ACH (min not zero): 11.9

Climate Change Annual Carbon Load

Watts Mechanical: 1,718
Watts UV-C: 0
Watts UV-Far: 0
Watts Other: 0
Watts Total: 1,718

Occupancy: 16 Hrs . 365 Days . 5840 Total Hours
Occupancy Duty Cycle (1-100): 95%
Occupied Hours: 5548

Occupied Kilo Watt Hours (kWh): 9,533
Unoccupied Kilo Watt Hours (kWh): 953
Total Kilo Watt Hours (kWh): 10,486

Total Watts per sqft: 0.954
Total Watts per cuft: 0.119
Total Watts per 1000 sqft: 954

Co2 (annual) lbs. Tons Metric Tons
Occupied 8,484 4.2 3.8
Unoccupied 848 0.4 0.4
Total 9,333 4.7 4.2

CO2 lbs. Tons Metric Tons
per 1000 sqft 5185 2.6 2.4
per 1 sqft 5.185 - -
per 1 cuft 0.648 - -


CAB v 0.11 R 3

02:13:14 Start Time
02:13:14 End Time
0 Seconds

5.026003 cab pid: 1395127 httpd pid: error pid: