About Us | Contact Us |
0. Space Type | BOS-School |
1. Establishment Name | Dearborn 6 12 STEM Academy |
2. Address | address |
3. City | Boston |
4. State / Province | MA |
5. Country | USA |
6. Date | 03/21/2021 |
7. Data Source | School District |
8. Performed by | External Company |
9. Company Name Address Contact | Cashins & Associates, Inc. 599 North Ave #8, Wakefield, MA 01880 |
10. Requirement Source | Boston School 3 ACH guideline |
11. Technology | Central HVAC |
12. Min ACH | 0.9 |
13. Max ACH | 4.4 |
14. Avg ACH | 2 |
15. eACH | 0 |
16. Filter MERV | --- |
17. Percent Outside Air | 100 |
18. ON and Ventilates Entire Indoor Area | Yes |
19. Vent Clearance min 6 ft | Yes |
20. No of Rooms | 6 |
21. sqft | 432 |
22. cuft | 4320 |
23. No of Buildings | 1 |
24. Comments | Source Boston School District March 18, 2021. https://www.bostonpublicschools.org/Page/8463 . https://drive.google.com/file/d/1bzam7XeMQDjjv7Og_86PS41K78hBEOfT/view . assumed 10ft ceiling. wACH windows provided in dataset. Calculated wACH from measured CFM rates in dataset do not match. Differences due to errors. Did not use calculated wACH. Room 280. Diffuser air volume (cfm) 302. % Outside air 100. Calculated air volume (cfm) outside 302. Calculated air volume (cfm) return 0. Filter efficiency (decimal) 0. Combined air volume (cfm) 302. ACH outside 1.3. ACH total 1.3. ACH Copy paste check (uses total or outside) 1.3. Room 360. Diffuser air volume (cfm) 205. % Outside air 100. Calculated air volume (cfm) outside 205. Calculated air volume (cfm) return 0. Filter efficiency (decimal) 0. Combined air volume (cfm) 205. ACH outside 0.9. ACH total 0.9. ACH Copy paste check (uses total or outside) 0.9. Room 372. Diffuser air volume (cfm) 979. % Outside air 100. Calculated air volume (cfm) outside 979. Calculated air volume (cfm) return 0. Filter efficiency (decimal) 0. Combined air volume (cfm) 979. ACH outside 4.4. ACH total 4.4. ACH Copy paste check (uses total or outside) 4.4. Room 402. Diffuser air volume (cfm) 748. % Outside air 100. Calculated air volume (cfm) outside 748. Calculated air volume (cfm) return 0. Filter efficiency (decimal) 0. Combined air volume (cfm) 748. ACH outside 3.3. ACH total 3.3. ACH Copy paste check (uses total or outside) 3.3. Room 472. Diffuser air volume (cfm) 240. % Outside air 100. Calculated air volume (cfm) outside 240. Calculated air volume (cfm) return 0. Filter efficiency (decimal) 0. Combined air volume (cfm) 240. ACH outside 1.1. ACH total 1.1. ACH Copy paste check (uses total or outside) 1.1. Room 105. Diffuser air volume (cfm) 220. % Outside air 100. Calculated air volume (cfm) outside 220. Calculated air volume (cfm) return 0. Filter efficiency (decimal) 0. Combined air volume (cfm) 220. ACH outside 3.1. ACH total 3.1. ACH Copy paste check (uses total or outside) 3.1. |