0. Space Type | BOS-School |
1. Establishment Name | Boston Community Leadership Acad |
2. Address | address |
3. City | Boston |
4. State / Province | MA |
5. Country | USA |
6. Date | 03/21/2021 |
7. Data Source | School District |
8. Performed by | External Company |
9. Company Name Address Contact | Cashins & Associates, Inc. 599 North Ave #8, Wakefield, MA 01880 |
10. Requirement Source | Boston School 3 ACH guideline |
11. Technology | Natural Ventilation Windows and Limited HVAC |
12. Min ACH | 1.8 |
13. Max ACH | 3.3 |
14. Avg ACH | 2.5 |
15. eACH | 0 |
16. Filter MERV | --- |
17. Percent Outside Air | 100 |
18. ON and Ventilates Entire Indoor Area | Yes |
19. Vent Clearance min 6 ft | Yes |
20. No of Rooms | 6 |
21. sqft | 900 |
22. cuft | 9000 |
23. No of Buildings | 1 |
24. Comments | Source Boston School District March 18, 2021. https://www.bostonpublicschools.org/Page/8463 . https://drive.google.com/file/d/1bzam7XeMQDjjv7Og_86PS41K78hBEOfT/view . assumed 10ft ceiling. wACH windows provided in dataset. Calculated wACH from measured CFM rates in dataset do not match. Differences due to errors. Did not use calculated wACH. Room 114. Diffuser air volume (cfm) 469. % Outside air 100. Calculated air volume (cfm) outside 469. Calculated air volume (cfm) return 0. Filter efficiency (decimal) 0. Combined air volume (cfm) 469. ACH outside 3.3. ACH merv filter return air 0.0. ACH total 3.3. ACH Copy paste check (uses total or outside) 3.1. Room 117. Diffuser air volume (cfm) 419. % Outside air 100. Calculated air volume (cfm) outside 419. Calculated air volume (cfm) return 0. Filter efficiency (decimal) 0. Combined air volume (cfm) 419. ACH outside 3.0. ACH merv filter return air 0.0. ACH total 3.0. ACH Copy paste check (uses total or outside) 3. Room 14. Diffuser air volume (cfm) 217. % Outside air 100. Calculated air volume (cfm) outside 217. Calculated air volume (cfm) return 0. Filter efficiency (decimal) 0. Combined air volume (cfm) 217. ACH outside 1.8. ACH merv filter return air 0.0. ACH total 1.8. ACH Copy paste check (uses total or outside) 1.8. Room 211. Diffuser air volume (cfm) 288. % Outside air 100. Calculated air volume (cfm) outside 288. Calculated air volume (cfm) return 0. Filter efficiency (decimal) 0. Combined air volume (cfm) 288. ACH outside 1.9. ACH merv filter return air 0.0. ACH total 1.9. ACH Copy paste check (uses total or outside) 1.9. Room 216. Diffuser air volume (cfm) 495. % Outside air 100. Calculated air volume (cfm) outside 495. Calculated air volume (cfm) return 0. Filter efficiency (decimal) 0. Combined air volume (cfm) 495. ACH outside 3.3. ACH merv filter return air 0.0. ACH total 3.3. ACH Copy paste check (uses total or outside) 3.3. Room 103. Diffuser air volume (cfm) 204. % Outside air 100. Calculated air volume (cfm) outside 204. Calculated air volume (cfm) return 0. Filter efficiency (decimal) 0. Combined air volume (cfm) 204. ACH outside 1.4. ACH merv filter return air 0.0. ACH total 1.4. ACH Copy paste check (uses total or outside) 1.4. |