0. Space Type | BOS-School |
1. Establishment Name | Mather Elementary |
2. Address | address |
3. City | Boston |
4. State / Province | MA |
5. Country | USA |
6. Date | 03/21/2021 |
7. Data Source | School District |
8. Performed by | External Company |
9. Company Name Address Contact | Cashins & Associates, Inc. 599 North Ave #8, Wakefield, MA 01880 |
10. Requirement Source | Boston School 3 ACH guideline |
11. Technology | Natural Ventilation Windows and Limited HVAC |
12. Min ACH | 0.5 |
13. Max ACH | 3.8 |
14. Avg ACH | 2 |
15. eACH | 0 |
16. Filter MERV | --- |
17. Percent Outside Air | 100 |
18. ON and Ventilates Entire Indoor Area | Yes |
19. Vent Clearance min 6 ft | Yes |
20. No of Rooms | 6 |
21. sqft | 942.5 |
22. cuft | 9425 |
23. No of Buildings | 1 |
24. Comments | Source Boston School District March 18, 2021. https://www.bostonpublicschools.org/Page/8463 . https://drive.google.com/file/d/1bzam7XeMQDjjv7Og_86PS41K78hBEOfT/view . assumed 10ft ceiling. wACH windows provided in dataset. Calculated wACH from measured CFM rates in dataset do not match. Differences due to errors. Did not use calculated wACH. Room 214. Diffuser air volume (cfm) 203. % Outside air 100. Calculated air volume (cfm) outside 203. Calculated air volume (cfm) return 0. Filter efficiency (decimal) 0. Combined air volume (cfm) 203. ACH outside 1.1. ACH merv filter return air 0.0. ACH total 1.1. ACH Copy paste check (uses total or outside) 1.1. Room 302. Diffuser air volume (cfm) 690. % Outside air 100. Calculated air volume (cfm) outside 690. Calculated air volume (cfm) return 0. Filter efficiency (decimal) 0. Combined air volume (cfm) 690. ACH outside 3.8. ACH merv filter return air 0.0. ACH total 3.8. ACH Copy paste check (uses total or outside) 3.8. Room 318. Diffuser air volume (cfm) 90. % Outside air 100. Calculated air volume (cfm) outside 90. Calculated air volume (cfm) return 0. Filter efficiency (decimal) 0. Combined air volume (cfm) 90. ACH outside 0.5. ACH merv filter return air 0.0. ACH total 0.5. ACH Copy paste check (uses total or outside) 0.5. Room 402. Diffuser air volume (cfm) 422. % Outside air 100. Calculated air volume (cfm) outside 422. Calculated air volume (cfm) return 0. Filter efficiency (decimal) 0. Combined air volume (cfm) 422. ACH outside 2.3. ACH merv filter return air 0.0. ACH total 2.3. ACH Copy paste check (uses total or outside) 2.3. Room 414. Diffuser air volume (cfm) 395. % Outside air 100. Calculated air volume (cfm) outside 395. Calculated air volume (cfm) return 0. Filter efficiency (decimal) 0. Combined air volume (cfm) 395. ACH outside 2.2. ACH merv filter return air 0.0. ACH total 2.2. ACH Copy paste check (uses total or outside) 2.2. Room 12. Diffuser air volume (cfm) 340. % Outside air 100. Calculated air volume (cfm) outside 340. Calculated air volume (cfm) return 0. Filter efficiency (decimal) 0. Combined air volume (cfm) 340. ACH outside 2.2. ACH merv filter return air 0.0. ACH total 2.2. ACH Copy paste check (uses total or outside) 2.1. |