About Us Contact Us

   
Facility Ventilation Rate And Status Panel


Ventilation    

Minimum

Lowest

Average

Highest

Expected

4

4

8

12

Actual

0

1.9

4.2

17.7

Rating

Very Low

Low

Low

Elite

Numbers are Air Changes Per Hour ACH + eACH

Facility Status NORMAL based on average
Facility Example HOA Clubhouse


   

Only Show Facility Status Panel Example HOA Clubhouse





   
Smartphone FVR APP

Search Facilities . Add Facility . Learn

Facility Ventilation

4.2

Average

Air Changes Per Hour
ACH + eACH


Site Survey

See Rooms
  
  
  
  
  
  
  
  
  
  
  
  <
  
  
  
  
Pick Scale: Airborne
Airborne Comfort Outdoors

Rating
Low

Facility Status NORMAL based on average
Facility
Example HOA Clubhouse all data


   

Show Only Smartphone Example HOA Clubhouse







Facility Status Details
Num Room Status Room Name Room Rating Room
cu-ft
Vent
CFH
cuft/hr
Num
of
Vents
Total
ACH
Vents
Clear
System
On
Show Room
1. NORMALBallroom Wall Exhaust Elite 23040 132048 2 17.7 yes no 1. All Views . Panel . Smartphone
2. NORMALBallroon Ceiling Vents Elite 23040 132750 12 17.7 yes no 2. All Views . Panel . Smartphone
3. NORMALKitchen Med 2080 23016 2 11 yes no 3. All Views . Panel . Smartphone
4. WARNINGLibrary Low 9900 40500 3 4 4. All Views . Panel . Smartphone
5. WARNINGSitting Room Low 14850 54000 4 3.6 5. All Views . Panel . Smartphone
6. WARNINGConference Room Low 9900 40500 3 4 6. All Views . Panel . Smartphone
7. FAILUREOffice Very Low 6000 0 0 0 7. All Views . Panel . Smartphone
8. NORMALExercise Room Low 18000 81000 6 4.5 8. All Views . Panel . Smartphone
9. WARNINGPool Room Low 16000 40500 3 2.5 9. All Views . Panel . Smartphone
10. FAILUREGame Room 1 Very Low 9000 30 1 0 fail 10. All Views . Panel . Smartphone
11. FAILUREGame Room 2 Very Low 9000 30 1 0 fail 11. All Views . Panel . Smartphone
12. FAILUREArts and Crafts Room Very Low 6000 30 1 0 fail 12. All Views . Panel . Smartphone
13. FAILUREWomens Room Very Low 3750 0 0 0 13. All Views . Panel . Smartphone
14. FAILUREWomens Shower Very Low 12000 0 0 0 14. All Views . Panel . Smartphone
15. FAILUREMens Room Very Low 3750 0 0 0 15. All Views . Panel . Smartphone
16. FAILUREMens Shower Very Low 12000 0 0 0 16. All Views . Panel . Smartphone
17. NORMALLobby Elite 7500 27000 2 15.6 17. All Views . Panel . Smartphone
18. WARNINGHall 1 Ballroom Low 10000 27000 2 2.7 18. All Views . Panel . Smartphone
19. WARNINGHall 2 Reception Low 14000 27000 2 1.9 19. All Views . Panel . Smartphone
20. NORMALHall 3 Pool Exercise Med 3000 27000 2 9 20. All Views . Panel . Smartphone
21. FAILUREHall 4 Game Area Very Low 9000 0 0 0 fail 21. All Views . Panel . Smartphone
22. FAILURESwimming Pool Very Low 0 0 0 22. All Views . Panel . Smartphone

Show Only Facility Status Details





   
Smartphone FVR APP


Facility Status Details

Num Room Name Status Rating Vents
ACH
Vents
Clear
System
On
Show Room
1. Ballroom Wall Exhaust NORMALElite 2 17.7 yes no Views . Panel . Smartphone
2. Ballroon Ceiling Vents NORMALElite 12 17.7 yes no Views . Panel . Smartphone
3. Kitchen NORMALMed 2 11 yes no Views . Panel . Smartphone
4. Library WARNINGLow 3 4 Views . Panel . Smartphone
5. Sitting Room WARNINGLow 4 3.6 Views . Panel . Smartphone
6. Conference Room WARNINGLow 3 4 Views . Panel . Smartphone
7. Office FAILUREVery Low 0 0 Views . Panel . Smartphone
8. Exercise Room NORMALLow 6 4.5 Views . Panel . Smartphone
9. Pool Room WARNINGLow 3 2.5 Views . Panel . Smartphone
10. Game Room 1 FAILUREVery Low 1 0 fail Views . Panel . Smartphone
11. Game Room 2 FAILUREVery Low 1 0 fail Views . Panel . Smartphone
12. Arts and Crafts Room FAILUREVery Low 1 0 fail Views . Panel . Smartphone
13. Womens Room FAILUREVery Low 0 0 Views . Panel . Smartphone
14. Womens Shower FAILUREVery Low 0 0 Views . Panel . Smartphone
15. Mens Room FAILUREVery Low 0 0 Views . Panel . Smartphone
16. Mens Shower FAILUREVery Low 0 0 Views . Panel . Smartphone
17. Lobby NORMALElite 2 15.6 Views . Panel . Smartphone
18. Hall 1 Ballroom WARNINGLow 2 2.7 Views . Panel . Smartphone
19. Hall 2 Reception WARNINGLow 2 1.9 Views . Panel . Smartphone
20. Hall 3 Pool Exercise NORMALMed 2 9 Views . Panel . Smartphone
21. Hall 4 Game Area FAILUREVery Low 0 0 fail Views . Panel . Smartphone
22. Swimming Pool FAILUREVery Low 0 0 Views . Panel . Smartphone

Scale: Permanently Set at Airborne
Facility / Room Rating
Facility Low
Room

Facility Status FAILURE based on average
Facility Example HOA Clubhouse


   

Show Only Smartphone Example HOA Clubhouse




Real Time Logs

Log Events: system on, system off, system ready, system standby, diagnostics, occupied, unoccupiled, system ready, system normal, warning, alarm, failure

Find:

Show Only: Warnings Alarms Failures entries out of 3

Date TimeFacility or RoomStatusACH Level
09/22/22 05:00 PM Ballroon Ceiling Vents occupied system off alarm ACH 5.7
09/22/22 05:10 PM Ballroon Ceiling Vents occupied system on normal ACH 5.7
09/22/22 07:10 PM Ballroon Ceiling Vents occupied system off alarm ACH 5.7
09/22/22 08:00 PM Ballroon Ceiling Vents unoccupied system off warning ACH 5.7

Entire Log File: Example HOA Clubhouse


Enter Manual Log Data

Date Time (mm/dd/yyyy hh:mm AM or PM) (e.g. 01/30/2022 07:45 AM)

Unoccupied Occupied     System Off System On