About Us Contact Us

Sustainable Ventilation Assessment & Rating System (SVARS)

Find or Enter SVARS Data

school, university, city, state, country, . for all
Find

example, house, etc
Reject

Hide Columns
0 1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18 19
20 21 22 23 24 25 26 27 28 29
30 31 32 33 34 35 36 37 38 39

Enter New Observation . File .

Load Saved Data

SVARS Search Results

The information presented here is self-reported and reported by researchers. If this information is incorrect contact us and we will update the information or provide you access to update the information.

Col:
0

1

7

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36
No-ActionsData Source *
Participant . info
Facility Name
q1
ML1
10
q2
ML1
10
q3
ML1
10
q4
ML2
20
q5
ML1
20
q6
ML2
20
q7
ML3
20
q8
ML2
10
q9
ML2
20
q10
ML2
20
q11
ML2
10
q12
ML2
20
q13
ML2
10
q14
ML3
10
q15
ML4
10
q16
ML4
10
q17
ML5
10
q18
ML4
10
q19
ML5
10
Maturity
Level
ScoreGrade
20
0%
40
0%
40
0%
35
0%
2230
24%
2226
24%
20
0%
23
0%
22
0%
20
0%
10
0%
20
0%
10
0%
10
0%
10
0%
10
0%
40
0%
30
0%
40
0%

SVARS Questions

  1. Does the organizations Climate Action Plan explicitly state that the ventilation requirements follow the 2024 CDC guideline to aim for 5+ ACH in all public spaces?
    Score = 10 Maturity Level = 1

    Results

  2. Is there a course grain ventilation carbon footprint model identifying the ACH level and carbon footprint for each building?
    Score = 10 Maturity Level = 1

    Results

  3. Is there a fine grain ventilation carbon footprint model identifying the ACH level and carbon footprint for each space / room?
    Score = 10 Maturity Level = 1

    Results

  4. Using design data has the ACH level been calculated for each space / room?
    Score = 20 * percent of spaces that have calculated ACH (Score = 20 * 10% = 2) Maturity Level = 2

    Results

  5. Using measured data has the ACH level been measured for each space / room?
    Score = 20 * percent of spaces that have measured ACH (Score = 20 * 10% = 2) Maturity Level = 1

    Results

  6. Do the public spaces have 5+ ACH?
    Score = 20 * percent of spaces that have 5+ ACH (Score = 20 * 10% = 2) Maturity Level = 2

    Results

  7. Is there a Ventilation Quality Improvement program that uses a formal Ventilation Quality Improvement Indicator (QII)?
    Score = 20 See: Link Maturity Level = 3

    Results

  8. Are there BAS / BMS / EMS systems in the public spaces / rooms?
    Score = 10 * percent of spaces that have the system(s) (Score = 10 * 10% = 1) Maturity Level = 2

    Results

  9. Do the BAS / BMS / EMS systems in the public spaces report the actual ACH levels and ventilation power usage kWh?
    Score = 20 * percent of spaces that have the system(s) (Score = 20 * 10% = 2) Maturity Level = 2

    Results

  10. Has the Green House Report separately reported Metered Ventilation Carbon footprint?
    Metered Score = 20 * percent of the facilities (Score = 20 * 10% = 2) Maturity Level = 2

    Results

  11. Has the Green House Report separately reported Modeled Ventilation Carbon footprint?
    Modeled Score = 10 * percent of the facilities (Score = 10 * 80% = 8) Maturity Level = 2

    It is understood that metered data may not be available. In this case modeled data may be used to determine the ventilation carbon footprint. There may be facilities that have no data. For example the Total Score = Metered Score + Modeled Score; Total Score = 2 + 8 = 10, where 10% of the facilities have no data.

    Results

  12. Has the Green House Report Identified the Average, Maximum, and Minimum ACH levels in all facilities?
    Score = 20 * percent of the facilities (Score = 20 * 100% = 20) Maturity Level = 2

    Results

  13. Is there an occupant satisfaction survey that meets or exceeds the minimum criteria specified in this SVARS?
    Score = 10 See: Link Maturity Level = 2

    Results

  14. If the room ventilation is controlled by the occupants, is there a sign stating to turn the ventilation On upon room entry and Off upon room exist?
    Score = 10 * percent of rooms (Score = 10 * 100% = 10) Maturity Level = 3

    When occupants visit a room they look for a thermostat or unit ventilator and turn on the Fan if there is a fan switch available and it is not physically locked. When there is a room thermostat, move the Fan switch from Auto to On. This will turn on the fan and it will stay on regardless of temperature.

    Results

  15. Is there a ventilation carbon footprint training session and or guidelines provided to all employees and room leaders using the room for an event?
    Score = 10 Maturity Level = 4

    Results

  16. Does each room have a ventilation certificate showing the room name, room size (area and height), room CFM, room ACH, date, and inspection authority?
    Score = 10 Maturity Level = 4

    Results

  17. Are the ACH levels of the rooms posted on the public Internet for public viewing?
    Score = 10 Maturity Level = 5

    Results

  18. Does each facility have a ventilation certificate showing the building name, min ACH, avg ACH, max ACH, date, and inspection authority?
    Score = 10 Maturity Level = 4

    Results

  19. Are the ACH levels of the facility posted on the public Internet for public viewing?
    Score = 10 Maturity Level = 5

    Results

  20. Comments


























SVARS v 0.1 R 450

02:34:07 Start Time
02:34:07 End Time
0 Seconds

5.026003 svars pid: 3022194 httpd pid: error pid: